Saw this yesterday. Possibly a bad weld on the boiler, more likely a bad OPV. From the green deposits near the leftmost heat exchangers and the discoloration of the fittings and tubing it looks to be a few years old, so I'm going with a bad OverPressure Valve coupled with a pressurestat that stuck closed causing a runaway heater.
It would not be user error. Even if a tech had set the PStat too high, the OPV should have popped before the boiler. The comment about someone noticing a high pressure reading is total BS... a runaway P-stat will go from normal pressure to blowing the OPV in 30 seconds. The barista might have had 45 seconds to notice something was up before the thing blew, if that is what happened.
In the last year, I've had three shops' machines blow OPVs due to pressurestats sticking. It happens all the time.
I like OPVs, a lot. This picture is why. Used to happen all the time until they became standard equipment.
Can anybody ID the machine? Not one I'm familiar with.